CS607 Assignment No 3

Solution :

a) Fuzzy Input Variables:
This proposed design of control system has four inputs: luminance intensity, luminance mode, temperature and humidity.

b) Output variables of fuzzy system:
Luminance controller, air conditioner, ceiling fan, air-cooler fan, water pump and heating unit.

c) Ranges:


Luminance intensity (cd)
MF Range
Luminance Mode
MF Range
Temperature
MF Range
Humidity (RH)
MF Range
Dark
0-33
Sleep/off
0-33
Cold
0-15
wet
0-33
Low
0-66
Candle light/safety
0-66
Cool
15-45
normal
0-66
nominal

Normal
33-100
Normal working
33-100
warm
30-60
dry
33-100
Very warm
45-80
Bright
66-100
Work/study/display
66-100
hot
60-100
Very dry
66-100
Very hot
80-100


Luminance controller
MF Range
Air Conditioner
MF Range
Off
0-30
Off
0-20
Low
0-60
Fan mod
0-40
Medium
30-90
Low
20-60
High
60-100
Medium
40-80


High
60-100


Low
80-100


Ceiling fan
MF Range
Air cooler fan
MF Range
Water pump
Mf range
Heating unit
Mf range
Off
0-30
Off
0-50
Off
0-50
High
0-50
Low
0-60
Low
0-100
Low
0-100
Low
0-100
Medium
30-100
High
50-100
High
50-100
off
50-100
High
60-100







Inference rules:
Rule base for light intensity control

Rule no
                                            input

         Luminance mode
    Luminance intensity
1


Sleep/off
Dark
Off
2
Low
Off
3
Normal
Off
4
bright
Off

5




Candle light/safety
Dark
Low
6
Low
Off
7
Normal
Off
8
bright
Off
9




Normal working
Dark
Medium
10
Low
Medium
11
Normal
Off
12
bright
Off
13



Work/study/display
Dark
High
14
Low
High
15
Normal
Medium
16
Bright
Off



Rule Base For Temperature And Humidity Control  In The  Premises

Rule no
                inputs
                                     outputs

temperature
humidity
Ceiling fan
Air cooler fan
Water pump
      Air conditioner
Heating unit
17
Cold
Wet
Off
Off
Off
Off
High
18
Cold
Normal
Off
Off
Off
Off
High
19
Cold
Dry
Off
Off
Off
Off
Low
20
Cool
Wet
Off
Off
Off
Off
High
21
Cool
Normal
Off
Off
Off
Off
Low
22
Cool
Dry
Off
Off
Off
Off
Low
23
Nominal
Wet
Off
Off
Off
Off
Low
24
nominal
normal
off
off
off
off
Off






Rule Base For Temperature And Humidity Control In Indoor Premises Containing Air-Cooler And Ceiling Fan

25
Worm
Wet
Off
Off
Off
None
Off
26
Worm
Normal
Low
Off
Off
None
Off
27
Very worm
Normal
Medium
Off
Off
None
Off
28
Hot
Normal
High
Off
Off
None
Off
29
Hot
Dry
Medium
Low
Low
None
Off
30
Hot
Very dry
Low
High
High
None
Off
31
Very hot
Normal
Low
Low
Low
None
Off
32
Very hot
Dry
Medium
High
High
None
Off
33
Very hot
Very dry
high
high
high
None
Off



Rule Base For Temperature And Humidity Control In Indoor Premises Containing Air-conditioners

34
Worm
Wet
None
None
None
Off
Off
35
Worm
Normal
None
None
None
Fan mod
Off
36
Very worm
Normal
None
None
None
Fan mod
Off
37
Hot
Normal
None
None
None
Low
Off
38
hot
Dry
None
None
None
Medium
Off
39
hot
Very dry
None
None
None
High
Off
40
Very hot
Normal
None
None
None
medium
off
41
Very hot
Very dry
none
none
none
Very high
off
42
Very hot
Very dry
none
none
none
Very high
off


Rule Base For Temperature And Humidity Control In Indoor Premises Containing ceiling fan

44
Warm
Normal
Low
None
None
None
Off
45
Very warm
Normal
medium
None
None
None
Off
46
Hot
Normal
medium
None
None
None
Off
47
Hot
Dry
medium
None
None
None
Off
48
Hot
Very dry
Low
None
None
None
Off
49
Very hot
Normal
High
None
None
None
Off
50
Very hot
Dry
High
None
None
None
Off
51
Very hot
Very dry
high
None
None
None
Off


Rule Base For Temperature And Humidity Control In Indoor Premises Containing Air-cooler

52
Warm
Wet
None
Off
Off
None
Off
53
Warm
Normal
None
Low
Off
None
Off
54
V.warm
Normal
None
High
Off
None
Off
55
Hot
normal
None
Low
Low
None
Off
56
Hot
Dry
None
High
Low
None
Off
57
Hot
Very dry
None
Low
High
None
Off
58
Very hot
Normal
None
High
Low
None

59
Very hot
Dry
None
High
High
None
Off
60
Very hot
Very dry
None
high
high
None
Off



e) Short summery of design algorithm
There are included fuzzier , inference kernel connected with knowledgebase and de-fuzzier in the proposed fuzzy logic system. The knowledgebase contains database , rule base and membership functions. The fuzzier converts the crisp values into Linguistics values.
The linguistics values are manipulated for inference engine. The kernel of the system provides the output according to the rule selector.
The rule selector select the rules according to the knowledgebase.  Knowledgebase comprises of database , rule base and membership functions. Rule base is built up carefully considering all possible effective situations. There have been incorporated four inputs variables: luminance intensity, luminance mode, temperature and humidity.
There are six outputs controlling appliances: luminance controller, air conditioner ,ceiling fan , air cooler fan, water pump and heating unit. There have been considered sixty rules for the effective situations focusing energy saving . there are used sixty operators for the rule selector. Luminance mode can be set according to the requirement.


<<Download>>

Post a Comment

Don't Forget To Join My FB Group VU Vicky
THANK YOU :)

Previous Post Next Post